Applications
- Instrumentation and general purpose use in both standard (P40), and corrosive environments (P40 NACE).
Features
- Superior regulation characteristics
- Rugged, corrosion-resistant construction
- Economical
- Self-relieving
- Standard tapped vent
- Excellent stability and repeatability
- Soft relief seat on P40
- Several mounting options
Specifications
P40 Regulator | P40 NACE Regulator | |
---|---|---|
Sensitivity | 1" ( 25.4 mm) Water Column | 1" ( 25.4 mm) Water Column |
Flow Capacity | 20 SCFM ( 565 LPM) | 20 SCFM (565 LPM) |
Effect of Supply Pressure variation (25 PSIG) on Outlet Pressure | < 0.2 PSIG (0.01 BAR) | < 0.2 PSIG (0.01 BAR) |
Exhaust Capacity (5 PSIG above 20 PSIG set point) | 0.1–0.45 SCFM Typical (2.8–12.7 LPM) | 0.1–0.45 SCFM Typical (2.8–12.7 LPM) |
Maximum Input/Supply Pressure | 250 PSIG (17.2 BAR) | 250 PSIG (17.2 BAR) |
Effect of Changes in Flow on Regulated Pressure (100 PSIG/6.9 BAR Supply) |
4 PSIG ( 0.3 BAR) over flow 10 SCFM ( 283 LPM) (1⁄4 NPT, 20 PSIG / 1.4 BAR set point) |
4 PSIG ( 0.3 BAR) over flow 10 SCFM ( 283 LPM) (1⁄4" NPT, 20 PSIG / 1.4 BAR set point) |
Output Pressure Ranges | 0-10 PSIG (0-0.7 BAR), 0-35 PSIG (0-2.4 BAR) 0-60 PSIG (0-4.1 BAR), 0-120 PSIG (0-8.3 BAR) |
0-10 PSI (0-0.7 BAR), 0-35 PSIG (0-2.4 BAR) 0-60 PSIG (0-4.1 BAR), 0-120 PSIG (0-8.3 BAR) |
Temperature Range | 0 to 160˚F (-18 to 71˚C) | 0 to 180˚F (-15 to 82˚C) |
Total Air Consumption @ Maximum Output | 0.1 SCFH (0.05 LPM) | 6 SCFH (2.8 LPM) |
Port Size | 1⁄4 NPT | 1⁄4 NPT |
Size | 2.5" X 2.5" X 5.63" (63.5 X 63.5 X 143 mm) | 2.5" X 2.5" X 5.63" (63.5 X 63.5 X 143 mm) |
Weight | 0.82 lb. (.37 kg) | 0.82 lb. (.37 kg) |